OPERATOR'S MANUAL
CLEAN BURN MODELS: CB-1400, CB-1800, and CB-2800
MULTI-OIL FURNACES
with CB-525-S2 BURNER
IMPORTANT FOR U.S. INSTALLATIONS: All installations must be made in accordance with state and local codes
which may differ from the information provided in this manual. Save these instructions for reference.
IMPORTANT FOR CANADIAN INSTALLATIONS: These instructions have been reviewed and accepted by
Underwriters' Laboratories of Canada as being appropriate for the installation of the ULC labelled products
identified herein. The use of these instructions for the installation of products NOT bearing the ULC label and
NOT identified herein may result in an unacceptable or hazardous installation.
IMPORTANT FOR CANADIAN INSTALLATIONS: The installation of this equipment is to be accomplished by
qualified personnel and in accordance with the regulation of authorities having jurisdiction and CSA Standard B 139,
Installation Code for Oil Burning Equipment.
PUBLICATION DATE: 12/15/01, Rev. 7 CLEAN BURN PART # 43081
U.L. Listed Used Oil
Burning Appliance
#MH15393 (N)
U.L.-C Listed
#CMP217
WARNING: DO NOT assemble, install, operate, or maintain this equipment without first
reading and understanding the information provided in this manual. Installation and
service must be accomplished by qualified personnel. Failure to follow all safety precautions
and procedures as stated in this manual may result in property damage, serious personal injury
or death.
Seitenansicht 0
1 2 3 4 5 6 ... 103 104

Inhaltsverzeichnis

Seite 1 - OPERATOR'S MANUAL

OPERATOR'S MANUALCLEAN BURN MODELS: CB-1400, CB-1800, and CB-2800MULTI-OIL FURNACESwith CB-525-S2 BURNERIMPORTANT FOR U.S. INSTALLATIONS: All i

Seite 2

Operator's Manual: Models CB-1400, CB-1800, and CB-28001-2For Your Safety...WARNING!STOPYOUR SAFETY IS AT STAKE!DO NOT INSTALL, OPERATE ORMAINTA

Seite 3 - COPYRIGHT

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-2BLACKORANGEPRIMARYOILFFTCAPACITORBURNERMOTORSWITCHCENTRIFICAL140WHITECONNECTOR (FACE)1

Seite 4

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-3AAIR SOL.400 WATTS BLOCK HEATER140°BKWHTRDGRNAIR PRESSUREPUMP ONCENTRIFUGAL SWITCHN. C

Seite 5 - TABLE OF CONTENTS

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-4

Seite 6

Operator's Manual: Models CB-1400, CB-1800, and CB-2800C-1APPENDIX CFurnace Service RecordFurnace Purchased: Date __________ From (name/phone)__

Seite 7

Operator's Manual: Models CB-1400, CB-1800, and CB-2800C-2

Seite 8

Operator's Manual: Models CB-1400, CB-1800, and CB-28001-3For Your Safety... (continued)WARNING: The Best Operator is a Careful Operator! By u

Seite 9 - SECTION 1: INTRODUCTION

Operator's Manual: Models CB-1400, CB-1800, and CB-28001-4For Your Safety... (continued)WARNING: DO NOT add inappropriate or hazardous material

Seite 10 - WARNING!

Operator's Manual: Models CB-1400, CB-1800, and CB-28002-1SECTION 2: UNPACKINGBefore assembling your furnace, you must accomplish the following

Seite 11

Operator's Manual: Models CB-1400, CB-1800, and CB-28002-2Warranty RegistrationFor proper warranty registration, Clean Burn requires that you fi

Seite 12

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-1SECTION 3: FURNACE ASSEMBLYUnderstanding AssemblyAssembling your Clean Burn Furnace i

Seite 13 - SECTION 2: UNPACKING

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-2FIGURE 3A - Overview of Furnace AssemblyNOTE: Furnace shown is CB-2800.Assembly of CB

Seite 14 - Warranty Registration

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-3FIGURE 3B - Three-dimensional View - Unit Heater Completely Assembled

Seite 15 - SECTION 3: FURNACE ASSEMBLY

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-4Installing the Observation PortCAUTION: The observation port must be correctly instal

Seite 16 - FRONT VIEW OF CABINET

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-5STOP! READ THIS NOW.The following information is critical to the proper assembly and

Seite 18

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-6Unit Heater Models: Installing the Fan AssemblyCAUTION: Ducting any Unit Heater Furn

Seite 19 - STOP! READ THIS NOW

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-7Central Furnace Models: Installing the Blower AssemblyNOTE: The following informatio

Seite 20

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-8Figure 3F - Detail of Blower Assembly and Installation of Blower on Furnace Cabinet14F

Seite 21

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-9Central Furnace Models: Installing the Blower Assembly (continued)Figure 3G - Detail

Seite 22

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-10Central Furnace Models: Installing the Blower Assembly (continued)Installing the Blo

Seite 23

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-11Central Furnace Models: Installing the Blower Assembly (continued)Installing the Mot

Seite 24

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-12Central Furnace Models: Installing the Blower Assembly (continued)Installing the Bel

Seite 25

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-13Figure 3J - Burner Nozzle and Electrode SpecificationsVIEW A-A3XVIEW B-BNOZZLE IS STA

Seite 26

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-14Installing the Burner (continued)Mounting the Burner on the Hinge BracketATTENTION: B

Seite 27 - FRONT VIEW -- BB

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-15Installing the Connector Block on the Furnace Door(continued)ATTENTION: The connecto

Seite 28

WARRANTY INFORMATIONTRADEMARKSThe Clean Burn logo is a trademark of Clean Burn, Inc. All other brand or product names mentioned are the registeredtra

Seite 29 - FRONT VIEW OF FURNACE

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-16Installing the Connector Block, Oil Line Tubing,and Air Line Tubing (continued)Figure

Seite 30

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-17NOTE: Your furnace is now assembled and ready for installation. Install the furnac

Seite 31

Operator's Manual: Models CB-1400, CB-1800, and CB-28003-18

Seite 32

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-1SECTION 4: FURNACE INSTALLATIONUnderstanding InstallationInstalling your Clean Burn f

Seite 33 - Understanding Installation

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-2Figure 4A - Typical Furnace InstallationNON-RESTRICTIVE"CLASS A" STACK CAPWA

Seite 34 - DEDICATED ELECTRIC CIRCUIT

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-3Figure 4B - Typical Furnace Installation - Detailed"2 WIRE" THERMOSTAT CABLE

Seite 35 - STACK SIZE

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-4Selecting a LocationGuidelines for Selecting a LocationThe location you select for you

Seite 36 - Selecting a Location

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-5Determining Air Flow From the Furnace (continued)Mounting the FurnaceAfter selecting a

Seite 37 - CB-2800 FURNACE

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-6Mounting the Furnace (continued)Floor MountingCAUTION: If you are installing your fur

Seite 38 - MIN. 18" (46 CM)

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-7Determining the Type of Oil TankIt is very important that you determine which type of

Seite 40

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-8Determining the Type of Oil Tank (continued)FIGURE 4E - Inside Above Ground Tank Insta

Seite 41

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-9Determining the Type of Oil Tank (continued)Specifications for Inside Above Ground Tan

Seite 42 - PUMP ELECTRICAL CIRCUIT

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-10Determining the Type of Oil Tank (continued)FIGURE 4F - Outside Above Ground Tank Ins

Seite 43

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-11Determining the Type of Oil Tank (continued)Specifications for Outside Above Ground T

Seite 44

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-12Determining the Type of Oil Tank (continued)FIGURE 4G - Underground Tank Installation

Seite 45

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-13Determining the Type of Oil Tank (continued)Specifications for Underground Tank Insta

Seite 46 - Installing the Oil Pump

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-14Installing the Oil PumpAfter determining the type of oil tank your furnace installati

Seite 47 - MOUNTING SURFACE

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-15Installing the Oil Pump (continued)Figure 4H - Detail of Pump Installation for Above

Seite 48 - Wiring the Furnace and Pump

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-16Wiring the Furnace and PumpWARNING: To avoid electrical shock, make sure that power

Seite 49 - Installing the Oil Lines

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-17Installing the Oil LinesYour furnace installation requires two oil lines:(1) Suction

Seite 50

TABLE OF CONTENTSSECTION 1: INTRODUCTION... 1-1Guide to this Manual

Seite 51 - Installing the Stack

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-18Installing the Suction Oil Line (continued)4. Install the canister filter in the suct

Seite 52 -

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-19Installing the Compressed Air Line (continued)4. Install a water trap or extractor/dr

Seite 53

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-20 SINGLE WALL STACKMIN. 24 GAUGE10 FT. (3 M) MINIMUM VERTICALSTACK HEIGHT&qu

Seite 54 - OBTAIN PROPER DRAFT

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-21Figure 4J - Installation of "Class A" Stack Through SidewallSINGLE WALL STA

Seite 55

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-22I885398" CLEAN BURN BAROMETRIC DAMPERINSTALLED IN SINGLE WALL TEEADJUST THIS WEI

Seite 56

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-23Installing the Stack PenetrationCAUTION: When running the stack through your ceiling

Seite 57 - SECTION 5: OIL PUMP PRIMING

Operator's Manual: Models CB-1400, CB-1800, and CB-28004-24Installing the Wall ThermostatATTENTION: Before installing the round Honeywell therm

Seite 58 - FOUR "ALLEN" BOLTS

Operator's Manual: Models CB-1400, CB-1800, and CB-28005-1SECTION 5: OIL PUMP PRIMINGUnderstanding Oil Pump PrimingPreparing your Clean Burn fu

Seite 59 - BLEEDER PORT

Operator's Manual: Models CB-1400, CB-1800, and CB-28005-2Preparing the Canister Filter for Pump PrimingATTENTION: Fill the canister filter wit

Seite 60 - PRESSURE OIL LINE

Operator's Manual: Models CB-1400, CB-1800, and CB-28005-3Preparing the Pump for Pump Priming1. Refer to Figure 5B.2. Use a 3/8" wrench to

Seite 61 - Activating the Pump

TABLE OF CONTENTSSECTION 4: FURNACE INSTALLATION (continued)Determining the Type of Oil Tank ...

Seite 62 - Adjusting the Pump Pressure

Operator's Manual: Models CB-1400, CB-1800, and CB-28005-4Preparing the Burner for Pump PrimingNOTE: It is necessary to allow the burner to war

Seite 63

Operator's Manual: Models CB-1400, CB-1800, and CB-28005-5Activating the PumpIMPORTANT NOTE: Activating the pump for pump priming involves runn

Seite 64

Operator's Manual: Models CB-1400, CB-1800, and CB-28005-6Establishing Proper Oil Flow at the Pump1. Within one minute after opening the bleeder

Seite 65 - Starting the Burner

Operator's Manual: Models CB-1400, CB-1800, and CB-28006-1I88312AIR REGULATORLOCKING NUTSAIR GAUGEOIL GAUGECOMBUSTIONOIL REGULATORAIR BANDSECTIO

Seite 66

Operator's Manual: Models CB-1400, CB-1800, and CB-28006-2Preparing the Burner for Startup (continued)6. Initial Adjustment of the Combustion Ai

Seite 67 - Using the Reset Button

Operator's Manual: Models CB-1400, CB-1800, and CB-28006-3Starting the Burner1. Turn the switch on the wall thermostat to HEAT and adjust the th

Seite 68

Operator's Manual: Models CB-1400, CB-1800, and CB-28006-4Starting the Burner (continued)5. Check the flame length after the burner has fired fo

Seite 69

Operator's Manual: Models CB-1400, CB-1800, and CB-28007-1SECTION 7: RESETTING THE OIL PRIMARY CONTROLUnderstanding the Oil Primary ControlThe

Seite 70 - BAROMETRIC DAMPER

Operator's Manual: Models CB-1400, CB-1800, and CB-28007-2

Seite 71

Operator's Manual: Models CB-1400, CB-1800, and CB-28008-1I88257SECTION 8: ADJUSTING THE DRAFT OVER FIREChecking for Correct Draft Over FireWAR

Seite 72 - EXHAUST FAN

TABLE OF CONTENTSSECTION 8: ADJUSTING THE DRAFT OVER FIRE ... 8-1Checking for Correct Draft Over Fire .

Seite 73

Operator's Manual: Models CB-1400, CB-1800, and CB-28008-2I88258ADJUST THIS WEIGHTTO OBTAIN PROPERDRAFT OVERFIRE BAROMETRIC DAMPERFigure 8B - Ad

Seite 74

Operator's Manual: Models CB-1400, CB-1800, and CB-28008-3Understanding the Effect of Exhaust Fans on DraftAny type of exhaust fan, paint booth,

Seite 75 - SECTION 9: MAINTENANCE

Operator's Manual: Models CB-1400, CB-1800, and CB-28008-4Figure 8C - Proper Draft vs. BackdraftRISING HOT COMBUSTION GASESPRODUCE DRAFT IN THE

Seite 76 - Cleaning the Canister Filter

Operator's Manual: Models CB-1400, CB-1800, and CB-28008-5Installing a Make-up Air LouverExhaust Fans and Make-up Air LouversWhen exhaust fans a

Seite 77 - Cleaning Ash from the Furnace

Operator's Manual: Models CB-1400, CB-1800, and CB-28008-6Installing the Make-up Air LouverNOTE: It is very important to follow these instructi

Seite 78 - (continued)

Operator's Manual: Models CB-1400, CB-1800, and CB-28009-1SECTION 9: MAINTENANCEUnderstanding MaintenanceMaintaining your Clean Burn furnace is

Seite 79 - Cleaning the Check Valve

Operator's Manual: Models CB-1400, CB-1800, and CB-28009-2Cleaning the Canister FilterNOTE: Never operate your furnace with more than 10"

Seite 80 - End of Season Maintenance

Operator's Manual: Models CB-1400, CB-1800, and CB-28009-3Cleaning Ash from the FurnaceNOTE: The maintenance interval for cleaning ash from the

Seite 81 - APPENDIX A

Operator's Manual: Models CB-1400, CB-1800, and CB-28009-4Cleaning the Ash(continued)4. Remove the clean-outdoor(s) to clean ash frominside the

Seite 82 - CB-2800

Operator's Manual: Models CB-1400, CB-1800, and CB-28009-5Cleaning the Ash (continued)j. Inspect the fiberglass rope gasket.NOTE: Make sure the

Seite 84

Operator's Manual: Models CB-1400, CB-1800, and CB-28009-6Cleaning the TankDO NOT allow water, sludge, or other debris to accumulate in your oil

Seite 85

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-1APPENDIX ADetailed Furnace SpecificationsFURNACE SPECIFICATION CB-1400 CB-1800 CB-2800

Seite 86 - CB − 525 − S2

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-2Burner Technical SpecificationsBurner CB-525-S2Ignition Transformer Carlin Transformer

Seite 87 - Burner Components (continued)

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-3Furnace Dimensions (CB-1400)I88545TOP VIEW (SHOWING MOUNTING LUGS)FRONT VIEW (BURNER S

Seite 88

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-4572 mm765 mm476 mm1045 mm587 mm394 mm1010 mm714 mm1257 mm WITH FAN INSTALLED765 mm714

Seite 89

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-5619 mmI88295TOP VIEW (SHOWING MOUNTING LUGS)FRONT VIEW (BURNER SIDE)BACK VIEW (FURNACE

Seite 90

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-6Burner ComponentsFIGURE A1 - Burner Component Detail356181920222123241510131112162526I

Seite 91

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-7Burner Components (continued)ITEM # PART # QTY PART DESCRIPTION 1 26103 1 AIR INTA

Seite 92 - Oil Pump Components

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-8142526243029593231(8)(8)11122154222321(2)(2)161819344142433940363845353344464729172037

Seite 93 - VACUUM GAUGE

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-9Burner Components (continued)ITEM # PART # QTY PART DESCRIPTION 1 34169 1 EL

Seite 94 - RED WIRE (CONNECT TO LIMIT)

Operator's Manual: Models CB-1400, CB-1800, and CB-28001-1SECTION 1: INTRODUCTIONGuide to this ManualThis manual contains all the information n

Seite 95 - APPENDIX B

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-10Burner Components (continued)FIGURE A3 - Burner Electrode Specifications with Spinner

Seite 96

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-11Burner Components (continued)Removing the Nozzle for Cleaning:NOTE: Due to swivel fi

Seite 97

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-12Oil Pump ComponentsFIGURE A5 - Oil Pump ComponentsPUMP MOTORPUMP HEADPUMP MOUNTCOUPLI

Seite 98

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-13Oil Pump Components (continued)Vacuum Testing the Oil PumpVacuum testing the oil pump

Seite 99

Operator's Manual: Models CB-1400, CB-1800, and CB-2800A-14Fan Limit ControlUnderstanding the Operation of the Fan Limit ControlThe fan limit co

Seite 100 - Wiring Diagrams

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-1APPENDIX BWiring DiagramsFIGURE B1 - Furnace Wiring DiagramL1L234L2WHITEWHITEBLACKWHIT

Seite 101 - DWG. No

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-2BLACKORANGEPRIMARYOILFFTCAPACITORBURNERMOTORSWITCHCENTRIFICAL140WHITECONNECTOR (FACE)1

Seite 102

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-3AAIR SOL.400 WATTS BLOCK HEATER140°BKWHTRDGRNAIR PRESSUREPUMP ONCENTRIFUGAL SWITCHN. C

Seite 103 - APPENDIX C

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-4

Seite 104

Operator's Manual: Models CB-1400, CB-1800, and CB-2800B-1APPENDIX BWiring DiagramsFIGURE B1 - Furnace Wiring DiagramL1L234L2WHITEWHITEBLACKWHIT